Maximum

SCPI Commands :

CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:EDRate:MAXimum
FETCh:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:EDRate:MAXimum
READ:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:EDRate:MAXimum
class MaximumCls[source]

Maximum commands group definition. 3 total commands, 0 Subgroups, 3 group commands

class CalculateStruct[source]

Response structure. Fields:

  • Reliability: int: decimal ‘Reliability indicator’

  • Out_Of_Tol: float or bool: float Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINKRESOLVED Configure.MultiEval.Scount#Modulation CMDLINKRESOLVED]) exceeding the specified limits. Range: 0 % to 100 %, Unit: %

  • Omega_I: float or bool: float Initial center frequency error Range: -0.99999 MHz to 0.99999 MHz, Unit: Hz

  • Omega_Iplus_Omega_0_Max: float or bool: float Maximum compensated frequency error Range: -0.99999 MHz to 0.99999 MHz, Unit: Hz

  • Omega_0_Max: float or bool: float Maximum compensated frequency error Range: -0.99999 MHz to 0.99999 MHz, Unit: Hz

  • Rms_Devm: float or bool: float Differential EVM results Range: 0 to 1

  • Peak_Devm: float or bool: float Range: 0 to 1

  • P_99_Devm: float or bool: float Range: 0 to 1

  • Nominal_Power: float or bool: float Average power during the carrier-on state Range: -99.99 dBm to 99.99 dBm, Unit: dBm

class ResultData[source]

Response structure. Fields:

  • Reliability: int: decimal ‘Reliability indicator’

  • Out_Of_Tol: float: float Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINKRESOLVED Configure.MultiEval.Scount#Modulation CMDLINKRESOLVED]) exceeding the specified limits. Range: 0 % to 100 %, Unit: %

  • Omega_I: float: float Initial center frequency error Range: -0.99999 MHz to 0.99999 MHz, Unit: Hz

  • Omega_Iplus_Omega_0_Max: float: float Maximum compensated frequency error Range: -0.99999 MHz to 0.99999 MHz, Unit: Hz

  • Omega_0_Max: float: float Maximum compensated frequency error Range: -0.99999 MHz to 0.99999 MHz, Unit: Hz

  • Rms_Devm: float: float Differential EVM results Range: 0 to 1

  • Peak_Devm: float: float Range: 0 to 1

  • P_99_Devm: float: float Range: 0 to 1

  • Nominal_Power: float: float Average power during the carrier-on state Range: -99.99 dBm to 99.99 dBm, Unit: dBm

calculate() CalculateStruct[source]
# SCPI: CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:EDRate:MAXimum
value: CalculateStruct = driver.multiEval.modulation.edrate.maximum.calculate()

Returns the modulation results for EDR packets. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

return:

structure: for return value, see the help for CalculateStruct structure arguments.

fetch() ResultData[source]
# SCPI: FETCh:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:EDRate:MAXimum
value: ResultData = driver.multiEval.modulation.edrate.maximum.fetch()

Returns the modulation results for EDR packets. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

return:

structure: for return value, see the help for ResultData structure arguments.

read() ResultData[source]
# SCPI: READ:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:EDRate:MAXimum
value: ResultData = driver.multiEval.modulation.edrate.maximum.read()

Returns the modulation results for EDR packets. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.

return:

structure: for return value, see the help for ResultData structure arguments.