Current
SCPI Commands :
CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy[:LE1M]:CURRent
READ:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy[:LE1M]:CURRent
FETCh:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy[:LE1M]:CURRent
- class CurrentCls[source]
Current commands group definition. 3 total commands, 0 Subgroups, 3 group commands
- class CalculateStruct[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability indicator’
Out_Of_Tol: float or bool: float Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINKRESOLVED Configure.MultiEval.Scount#PowerVsTime CMDLINKRESOLVED]) exceeding the specified limits, see [CMDLINKRESOLVED Configure.MultiEval.Limit.LowEnergy.Le1M.PowerVsTime#set CMDLINKRESOLVED]. Range: 0 % to 100 %, Unit: %
Nominal_Power: float or bool: float Average power during the carrier-on state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
Peak_Power: float or bool: float Peak power during the carrier-on state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
Leakage_Power: float or bool: float Average power during the carrier-off state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
Peak_Min_Avg_Pow: float or bool: float Peak power minus average power Range: -99.99 dBm to 99.99 dBm, Unit: dBm
- class FetchStruct[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability indicator’
Out_Of_Tol: float: float Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINKRESOLVED Configure.MultiEval.Scount#PowerVsTime CMDLINKRESOLVED]) exceeding the specified limits, see [CMDLINKRESOLVED Configure.MultiEval.Limit.LowEnergy.Le1M.PowerVsTime#set CMDLINKRESOLVED]. Range: 0 % to 100 %, Unit: %
Nominal_Power: float: float Average power during the carrier-on state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
Peak_Power: float: float Peak power during the carrier-on state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
Leakage_Power: float: float Average power during the carrier-off state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
Peak_Min_Avg_Pow: float: float Peak power minus average power Range: -99.99 dBm to 99.99 dBm, Unit: dBm
- class ReadStruct[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability indicator’
Out_Of_Tol: float or bool: float Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINKRESOLVED Configure.MultiEval.Scount#PowerVsTime CMDLINKRESOLVED]) exceeding the specified limits, see [CMDLINKRESOLVED Configure.MultiEval.Limit.LowEnergy.Le1M.PowerVsTime#set CMDLINKRESOLVED]. Range: 0 % to 100 %, Unit: %
Nominal_Power: float: float Average power during the carrier-on state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
Peak_Power: float: float Peak power during the carrier-on state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
Leakage_Power: float: float Average power during the carrier-off state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
Peak_Min_Avg_Pow: float: float Peak power minus average power Range: -99.99 dBm to 99.99 dBm, Unit: dBm
- calculate() CalculateStruct [source]
# SCPI: CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy[:LE1M]:CURRent value: CalculateStruct = driver.multiEval.powerVsTime.lowEnergy.le1M.current.calculate()
Returns the power results for LE 1M PHY (uncoded) . The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for CalculateStruct structure arguments.
- fetch() FetchStruct [source]
# SCPI: FETCh:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy[:LE1M]:CURRent value: FetchStruct = driver.multiEval.powerVsTime.lowEnergy.le1M.current.fetch()
Returns the power results for LE 1M PHY (uncoded) . The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for FetchStruct structure arguments.
- read() ReadStruct [source]
# SCPI: READ:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy[:LE1M]:CURRent value: ReadStruct = driver.multiEval.powerVsTime.lowEnergy.le1M.current.read()
Returns the power results for LE 1M PHY (uncoded) . The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return: