Current¶
SCPI Commands
CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy:LRANge:CURRent
READ:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy:LRANge:CURRent
FETCh:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy:LRANge:CURRent
- class Current[source]
Current commands group definition. 3 total commands, 0 Sub-groups, 3 group commands
- class CalculateStruct[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability Indicator’
Out_Of_Tol: float: float | ON | OFF Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINK: CONFigure:BLUetooth:MEASi:MEValuation:SCOunt:PVTime CMDLINK]) exceeding the specified limits, see [CMDLINK: CONFigure:BLUetooth:MEASi:MEValuation:LIMit:LENergy:LE2M:PVTime CMDLINK] and [CMDLINK: CONFigure:BLUetooth:MEASi:MEValuation:LIMit:LENergy:LRANge:PVTime CMDLINK]. Range: 0 % to 100 %, Unit: %
Nominal_Power: float: float Average power during the carrier-on state Range: -128 dBm to 30 dBm , Unit: dBm
Peak_Power: float: float Peak power during the carrier-on state Range: -128 dBm to 30 dBm , Unit: dBm
Leakage_Power: float: float Average power during the carrier-off state Range: -128 dBm to 30 dBm , Unit: dBm
Peak_Min_Avg_Pow: float: float Peak power minus average power Range: 0 dB to 158 dB , Unit: dB
- class FetchStruct[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability Indicator’
Out_Of_Tol: float: float | ON | OFF Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINK: CONFigure:BLUetooth:MEASi:MEValuation:SCOunt:PVTime CMDLINK]) exceeding the specified limits, see [CMDLINK: CONFigure:BLUetooth:MEASi:MEValuation:LIMit:LENergy:LE2M:PVTime CMDLINK] and [CMDLINK: CONFigure:BLUetooth:MEASi:MEValuation:LIMit:LENergy:LRANge:PVTime CMDLINK]. Range: 0 % to 100 %, Unit: %
Nominal_Power: float: float Average power during the carrier-on state Range: -128 dBm to 30 dBm , Unit: dBm
Peak_Power: float: float Peak power during the carrier-on state Range: -128 dBm to 30 dBm , Unit: dBm
Leakage_Power: float: float Average power during the carrier-off state Range: -128 dBm to 30 dBm , Unit: dBm
Peak_Min_Avg_Pow: float: float Peak power minus average power Range: 0 dB to 158 dB , Unit: dB
- class ReadStruct[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability Indicator’
Out_Of_Tol: float or bool: float | ON | OFF Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINK: CONFigure:BLUetooth:MEASi:MEValuation:SCOunt:PVTime CMDLINK]) exceeding the specified limits, see [CMDLINK: CONFigure:BLUetooth:MEASi:MEValuation:LIMit:LENergy:LE2M:PVTime CMDLINK] and [CMDLINK: CONFigure:BLUetooth:MEASi:MEValuation:LIMit:LENergy:LRANge:PVTime CMDLINK]. Range: 0 % to 100 %, Unit: %
Nominal_Power: float: float Average power during the carrier-on state Range: -128 dBm to 30 dBm , Unit: dBm
Peak_Power: float: float Peak power during the carrier-on state Range: -128 dBm to 30 dBm , Unit: dBm
Leakage_Power: float: float Average power during the carrier-off state Range: -128 dBm to 30 dBm , Unit: dBm
Peak_Min_Avg_Pow: float: float Peak power minus average power Range: 0 dB to 158 dB , Unit: dB
- calculate() → CalculateStruct[source]
# SCPI: CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy:LRANge:CURRent value: CalculateStruct = driver.multiEval.powerVsTime.lowEnergy.lrange.current.calculate()
Returns the power results for LE 2M PHY (…:LE2M…) and LE coded PHY (…:LRANge…) . The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return
structure: for return value, see the help for CalculateStruct structure arguments.
- fetch() → FetchStruct[source]
# SCPI: FETCh:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy:LRANge:CURRent value: FetchStruct = driver.multiEval.powerVsTime.lowEnergy.lrange.current.fetch()
Returns the power results for LE 2M PHY (…:LE2M…) and LE coded PHY (…:LRANge…) . The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return
structure: for return value, see the help for FetchStruct structure arguments.
- read() → ReadStruct[source]
# SCPI: READ:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy:LRANge:CURRent value: ReadStruct = driver.multiEval.powerVsTime.lowEnergy.lrange.current.read()
Returns the power results for LE 2M PHY (…:LE2M…) and LE coded PHY (…:LRANge…) . The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return
structure: for return value, see the help for ReadStruct structure arguments.