Source code for RsCmwBluetoothMeas.Implementations.MultiEval.Frange.Brate.Current

from .....Internal.Core import Core
from .....Internal.CommandsGroup import CommandsGroup
from .....Internal.StructBase import StructBase
from .....Internal.ArgStruct import ArgStruct


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs] class CurrentCls: """Current commands group definition. 3 total commands, 0 Subgroups, 3 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("current", core, parent) # noinspection PyTypeChecker
[docs] class CalculateStruct(StructBase): """Response structure. Fields: \n - Reliability: int: decimal 'Reliability indicator' - Out_Of_Tol: float or bool: float | ON | OFF Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINKRESOLVED Configure.MultiEval.Scount#Frange CMDLINKRESOLVED]) exceeding the specified limit. (see [CMDLINKRESOLVED Configure.MultiEval.Limit.Frange#set CMDLINKRESOLVED]) Additional ON/OFF enables/disables the out of tolerance evaluation. Range: 0 % to 100 % - Nominal_Power: float or bool: float Average power during the carrier-on state Range: -128 dBm to 30 dBm - Fl: float or bool: float Lowest frequency at which spectral power density drops below specified threshold Range: -1 MHz to +1 MHz - Fh: float or bool: float Highest frequency at which spectral power density drops below specified threshold Range: -1 MHz to +1 MHz""" __meta_args_list = [ ArgStruct.scalar_int('Reliability', 'Reliability'), ArgStruct.scalar_float_ext('Out_Of_Tol'), ArgStruct.scalar_float_ext('Nominal_Power'), ArgStruct.scalar_float_ext('Fl'), ArgStruct.scalar_float_ext('Fh')] def __init__(self): StructBase.__init__(self, self) self.Reliability: int = None self.Out_Of_Tol: float or bool = None self.Nominal_Power: float or bool = None self.Fl: float or bool = None self.Fh: float or bool = None
[docs] def calculate(self) -> CalculateStruct: """SCPI: CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:FRANge:BRATe:CURRent \n Snippet: value: CalculateStruct = driver.multiEval.frange.brate.current.calculate() \n Returns the 'Frequency Range' results for BR. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below. \n :return: structure: for return value, see the help for CalculateStruct structure arguments.""" return self._core.io.query_struct(f'CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:FRANge:BRATe:CURRent?', self.__class__.CalculateStruct())
# noinspection PyTypeChecker
[docs] class ReadStruct(StructBase): """Response structure. Fields: \n - Reliability: int: decimal 'Reliability indicator' - Out_Of_Tol: float or bool: float | ON | OFF Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINKRESOLVED Configure.MultiEval.Scount#Frange CMDLINKRESOLVED]) exceeding the specified limit. (see [CMDLINKRESOLVED Configure.MultiEval.Limit.Frange#set CMDLINKRESOLVED]) Additional ON/OFF enables/disables the out of tolerance evaluation. Range: 0 % to 100 % - Nominal_Power: float: float Average power during the carrier-on state Range: -128 dBm to 30 dBm - Fl: float: float Lowest frequency at which spectral power density drops below specified threshold Range: -1 MHz to +1 MHz - Fh: float: float Highest frequency at which spectral power density drops below specified threshold Range: -1 MHz to +1 MHz""" __meta_args_list = [ ArgStruct.scalar_int('Reliability', 'Reliability'), ArgStruct.scalar_float_ext('Out_Of_Tol'), ArgStruct.scalar_float('Nominal_Power'), ArgStruct.scalar_float('Fl'), ArgStruct.scalar_float('Fh')] def __init__(self): StructBase.__init__(self, self) self.Reliability: int = None self.Out_Of_Tol: float or bool = None self.Nominal_Power: float = None self.Fl: float = None self.Fh: float = None
[docs] def read(self) -> ReadStruct: """SCPI: READ:BLUetooth:MEASurement<Instance>:MEValuation:FRANge:BRATe:CURRent \n Snippet: value: ReadStruct = driver.multiEval.frange.brate.current.read() \n Returns the 'Frequency Range' results for BR. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below. \n :return: structure: for return value, see the help for ReadStruct structure arguments.""" return self._core.io.query_struct(f'READ:BLUetooth:MEASurement<Instance>:MEValuation:FRANge:BRATe:CURRent?', self.__class__.ReadStruct())
# noinspection PyTypeChecker
[docs] class FetchStruct(StructBase): """Response structure. Fields: \n - Reliability: int: decimal 'Reliability indicator' - Out_Of_Tol: float: float | ON | OFF Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINKRESOLVED Configure.MultiEval.Scount#Frange CMDLINKRESOLVED]) exceeding the specified limit. (see [CMDLINKRESOLVED Configure.MultiEval.Limit.Frange#set CMDLINKRESOLVED]) Additional ON/OFF enables/disables the out of tolerance evaluation. Range: 0 % to 100 % - Nominal_Power: float: float Average power during the carrier-on state Range: -128 dBm to 30 dBm - Fl: float: float Lowest frequency at which spectral power density drops below specified threshold Range: -1 MHz to +1 MHz - Fh: float: float Highest frequency at which spectral power density drops below specified threshold Range: -1 MHz to +1 MHz""" __meta_args_list = [ ArgStruct.scalar_int('Reliability', 'Reliability'), ArgStruct.scalar_float('Out_Of_Tol'), ArgStruct.scalar_float('Nominal_Power'), ArgStruct.scalar_float('Fl'), ArgStruct.scalar_float('Fh')] def __init__(self): StructBase.__init__(self, self) self.Reliability: int = None self.Out_Of_Tol: float = None self.Nominal_Power: float = None self.Fl: float = None self.Fh: float = None
[docs] def fetch(self) -> FetchStruct: """SCPI: FETCh:BLUetooth:MEASurement<Instance>:MEValuation:FRANge:BRATe:CURRent \n Snippet: value: FetchStruct = driver.multiEval.frange.brate.current.fetch() \n Returns the 'Frequency Range' results for BR. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below. \n :return: structure: for return value, see the help for FetchStruct structure arguments.""" return self._core.io.query_struct(f'FETCh:BLUetooth:MEASurement<Instance>:MEValuation:FRANge:BRATe:CURRent?', self.__class__.FetchStruct())