from ......Internal.Core import Core
from ......Internal.CommandsGroup import CommandsGroup
from ......Internal.StructBase import StructBase
from ......Internal.ArgStruct import ArgStruct
# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]
class MaximumCls:
"""Maximum commands group definition. 3 total commands, 0 Subgroups, 3 group commands"""
def __init__(self, core: Core, parent):
self._core = core
self._cmd_group = CommandsGroup("maximum", core, parent)
# noinspection PyTypeChecker
[docs]
class CalculateStruct(StructBase):
"""Response structure. Fields: \n
- Reliability: int: decimal 'Reliability indicator'
- Out_Of_Tol: float or bool: float Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINKRESOLVED Configure.MultiEval.Scount#PowerVsTime CMDLINKRESOLVED]) exceeding the specified limits, see [CMDLINKRESOLVED Configure.MultiEval.Limit.LowEnergy.Le1M.PowerVsTime#set CMDLINKRESOLVED]. Range: 0 % to 100 %, Unit: %
- Nominal_Power: float or bool: float Average power during the carrier-on state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
- Peak_Power: float or bool: float Peak power during the carrier-on state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
- Leakage_Power: float or bool: float Average power during the carrier-off state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
- Peak_Min_Avg_Pow: float or bool: float Peak power minus average power Range: -99.99 dBm to 99.99 dBm, Unit: dBm"""
__meta_args_list = [
ArgStruct.scalar_int('Reliability', 'Reliability'),
ArgStruct.scalar_float_ext('Out_Of_Tol'),
ArgStruct.scalar_float_ext('Nominal_Power'),
ArgStruct.scalar_float_ext('Peak_Power'),
ArgStruct.scalar_float_ext('Leakage_Power'),
ArgStruct.scalar_float_ext('Peak_Min_Avg_Pow')]
def __init__(self):
StructBase.__init__(self, self)
self.Reliability: int = None
self.Out_Of_Tol: float or bool = None
self.Nominal_Power: float or bool = None
self.Peak_Power: float or bool = None
self.Leakage_Power: float or bool = None
self.Peak_Min_Avg_Pow: float or bool = None
[docs]
def calculate(self) -> CalculateStruct:
"""SCPI: CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy[:LE1M]:MAXimum \n
Snippet: value: CalculateStruct = driver.multiEval.powerVsTime.lowEnergy.le1M.maximum.calculate() \n
Returns the power results for LE 1M PHY (uncoded) . The values described below are returned by FETCh and READ commands.
CALCulate commands return limit check results instead, one value for each result listed below. \n
:return: structure: for return value, see the help for CalculateStruct structure arguments."""
return self._core.io.query_struct(f'CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy:LE1M:MAXimum?', self.__class__.CalculateStruct())
# noinspection PyTypeChecker
[docs]
class ReadStruct(StructBase):
"""Response structure. Fields: \n
- Reliability: int: decimal 'Reliability indicator'
- Out_Of_Tol: float or bool: float Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINKRESOLVED Configure.MultiEval.Scount#PowerVsTime CMDLINKRESOLVED]) exceeding the specified limits, see [CMDLINKRESOLVED Configure.MultiEval.Limit.LowEnergy.Le1M.PowerVsTime#set CMDLINKRESOLVED]. Range: 0 % to 100 %, Unit: %
- Nominal_Power: float: float Average power during the carrier-on state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
- Peak_Power: float: float Peak power during the carrier-on state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
- Leakage_Power: float: float Average power during the carrier-off state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
- Peak_Min_Avg_Pow: float: float Peak power minus average power Range: -99.99 dBm to 99.99 dBm, Unit: dBm"""
__meta_args_list = [
ArgStruct.scalar_int('Reliability', 'Reliability'),
ArgStruct.scalar_float_ext('Out_Of_Tol'),
ArgStruct.scalar_float('Nominal_Power'),
ArgStruct.scalar_float('Peak_Power'),
ArgStruct.scalar_float('Leakage_Power'),
ArgStruct.scalar_float('Peak_Min_Avg_Pow')]
def __init__(self):
StructBase.__init__(self, self)
self.Reliability: int = None
self.Out_Of_Tol: float or bool = None
self.Nominal_Power: float = None
self.Peak_Power: float = None
self.Leakage_Power: float = None
self.Peak_Min_Avg_Pow: float = None
[docs]
def read(self) -> ReadStruct:
"""SCPI: READ:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy[:LE1M]:MAXimum \n
Snippet: value: ReadStruct = driver.multiEval.powerVsTime.lowEnergy.le1M.maximum.read() \n
Returns the power results for LE 1M PHY (uncoded) . The values described below are returned by FETCh and READ commands.
CALCulate commands return limit check results instead, one value for each result listed below. \n
:return: structure: for return value, see the help for ReadStruct structure arguments."""
return self._core.io.query_struct(f'READ:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy:LE1M:MAXimum?', self.__class__.ReadStruct())
# noinspection PyTypeChecker
[docs]
class FetchStruct(StructBase):
"""Response structure. Fields: \n
- Reliability: int: decimal 'Reliability indicator'
- Out_Of_Tol: float: float Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINKRESOLVED Configure.MultiEval.Scount#PowerVsTime CMDLINKRESOLVED]) exceeding the specified limits, see [CMDLINKRESOLVED Configure.MultiEval.Limit.LowEnergy.Le1M.PowerVsTime#set CMDLINKRESOLVED]. Range: 0 % to 100 %, Unit: %
- Nominal_Power: float: float Average power during the carrier-on state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
- Peak_Power: float: float Peak power during the carrier-on state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
- Leakage_Power: float: float Average power during the carrier-off state Range: -99.99 dBm to 99.99 dBm, Unit: dBm
- Peak_Min_Avg_Pow: float: float Peak power minus average power Range: -99.99 dBm to 99.99 dBm, Unit: dBm"""
__meta_args_list = [
ArgStruct.scalar_int('Reliability', 'Reliability'),
ArgStruct.scalar_float('Out_Of_Tol'),
ArgStruct.scalar_float('Nominal_Power'),
ArgStruct.scalar_float('Peak_Power'),
ArgStruct.scalar_float('Leakage_Power'),
ArgStruct.scalar_float('Peak_Min_Avg_Pow')]
def __init__(self):
StructBase.__init__(self, self)
self.Reliability: int = None
self.Out_Of_Tol: float = None
self.Nominal_Power: float = None
self.Peak_Power: float = None
self.Leakage_Power: float = None
self.Peak_Min_Avg_Pow: float = None
[docs]
def fetch(self) -> FetchStruct:
"""SCPI: FETCh:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy[:LE1M]:MAXimum \n
Snippet: value: FetchStruct = driver.multiEval.powerVsTime.lowEnergy.le1M.maximum.fetch() \n
Returns the power results for LE 1M PHY (uncoded) . The values described below are returned by FETCh and READ commands.
CALCulate commands return limit check results instead, one value for each result listed below. \n
:return: structure: for return value, see the help for FetchStruct structure arguments."""
return self._core.io.query_struct(f'FETCh:BLUetooth:MEASurement<Instance>:MEValuation:PVTime:LENergy:LE1M:MAXimum?', self.__class__.FetchStruct())