Measurement

SCPI Command :

CONFigure:BLUetooth:MEASurement<Instance>:MEValuation:SACP:LENergy[:LE1M]:MEASurement:MODE
class MeasurementCls[source]

Measurement commands group definition. 1 total commands, 0 Subgroups, 1 group commands

get_mode() LeChannelsRange[source]
# SCPI: CONFigure:BLUetooth:MEASurement<Instance>:MEValuation:SACP:LENergy[:LE1M]:MEASurement:MODE
value: enums.LeChannelsRange = driver.configure.multiEval.sacp.lowEnergy.le1M.measurement.get_mode()

Specifies the channel range for ACP measurements. It can be selected to cover either the full LE frequency band (forty 2 MHz channels) or only the adjacency of the current LE channel (ten 2 MHz channels) . The commands for LE 1M PHY (…:LE1M. ..) and LE 2M PHY (…:LE2M…) are available. Note: Although LE channels are 2 MHz wide, the channel width in ACP measurements is always 1 MHz (‘half-channel’) .

return:

meas_mode: CH40 | CH10 CH10: ‘ACP +/- 5 Channels’ - covers the current and its 10 adjacent 2 MHz LE channels (5 to the left, 5 to the right) . The R&S CMW measures the 1 MHz channels centered at fTX – 10 MHz, …, fTX + 10 MHz. CH40: ‘LE All Channels’ - covers all 40 LE channels. The R&S CMW measures the 81 half-channels centered at 2401 MHz, 2402 MHz, …, 2481 MHz.

set_mode(meas_mode: LeChannelsRange) None[source]
# SCPI: CONFigure:BLUetooth:MEASurement<Instance>:MEValuation:SACP:LENergy[:LE1M]:MEASurement:MODE
driver.configure.multiEval.sacp.lowEnergy.le1M.measurement.set_mode(meas_mode = enums.LeChannelsRange.CH10)

Specifies the channel range for ACP measurements. It can be selected to cover either the full LE frequency band (forty 2 MHz channels) or only the adjacency of the current LE channel (ten 2 MHz channels) . The commands for LE 1M PHY (…:LE1M. ..) and LE 2M PHY (…:LE2M…) are available. Note: Although LE channels are 2 MHz wide, the channel width in ACP measurements is always 1 MHz (‘half-channel’) .

param meas_mode:

CH40 | CH10 CH10: ‘ACP +/- 5 Channels’ - covers the current and its 10 adjacent 2 MHz LE channels (5 to the left, 5 to the right) . The R&S CMW measures the 1 MHz channels centered at fTX – 10 MHz, …, fTX + 10 MHz. CH40: ‘LE All Channels’ - covers all 40 LE channels. The R&S CMW measures the 81 half-channels centered at 2401 MHz, 2402 MHz, …, 2481 MHz.