Le1M
SCPI Commands :
CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:SACP:NMODe:LENergy[:LE1M]
FETCh:BLUetooth:MEASurement<Instance>:MEValuation:SACP:NMODe:LENergy[:LE1M]
READ:BLUetooth:MEASurement<Instance>:MEValuation:SACP:NMODe:LENergy[:LE1M]
- class Le1MCls[source]
Le1M commands group definition. 3 total commands, 0 Subgroups, 3 group commands
- class CalculateStruct[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability indicator’
Nominal_Power: float or bool: float Average power during the carrier-on state Range: -128.0 dBm to +30.0 dBm , Unit: dBm
No_Of_Exceptions: float or bool: decimal Number of exceptions (channels ±3, ±4 … with an ACP above the ‘Exception PTx’ threshold ) Range: 0 to 99
- class ResultData[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability indicator’
Nominal_Power: float: float Average power during the carrier-on state Range: -128.0 dBm to +30.0 dBm , Unit: dBm
No_Of_Exceptions: int: decimal Number of exceptions (channels ±3, ±4 … with an ACP above the ‘Exception PTx’ threshold ) Range: 0 to 99
- calculate() CalculateStruct [source]
# SCPI: CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:SACP:NMODe:LENergy[:LE1M] value: CalculateStruct = driver.multiEval.sacp.nmode.lowEnergy.le1M.calculate()
Returns the ‘Spectrum ACP’ results for LE normal mode, see ‘View Spectrum ACP’. Commands for uncoded LE 1M PHY (..:LE1M.. ) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for CalculateStruct structure arguments.
- fetch() ResultData [source]
# SCPI: FETCh:BLUetooth:MEASurement<Instance>:MEValuation:SACP:NMODe:LENergy[:LE1M] value: ResultData = driver.multiEval.sacp.nmode.lowEnergy.le1M.fetch()
Returns the ‘Spectrum ACP’ results for LE normal mode, see ‘View Spectrum ACP’. Commands for uncoded LE 1M PHY (..:LE1M.. ) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for ResultData structure arguments.
- read() ResultData [source]
# SCPI: READ:BLUetooth:MEASurement<Instance>:MEValuation:SACP:NMODe:LENergy[:LE1M] value: ResultData = driver.multiEval.sacp.nmode.lowEnergy.le1M.read()
Returns the ‘Spectrum ACP’ results for LE normal mode, see ‘View Spectrum ACP’. Commands for uncoded LE 1M PHY (..:LE1M.. ) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for ResultData structure arguments.