StandardDev¶
SCPI Commands
FETCh:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:LENergy:LRANge:SDEViation
CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:LENergy:LRANge:SDEViation
READ:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:LENergy:LRANge:SDEViation
- class StandardDev[source]
StandardDev commands group definition. 3 total commands, 0 Sub-groups, 3 group commands
- class CalculateStruct[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability Indicator’
Out_Of_Tol: float: float Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINK: CONFigure:BLUetooth:MEASi:MEValuation:SCOunt:MODulation CMDLINK]) exceeding the specified limits, see ‘Limits (Modulation LE) ‘. Range: 0 % to 100 %, Unit: %
Delta_F_199_P_9: float: float Range: -0.99999 MHz to 0.99999 MHz, Unit: Hz
Freq_Accuracy: float: float Range: -0.99999 MHz to 0.99999 MHz, Unit: Hz
Freq_Drift: float: float Range: -0.99999 MHz to 0.99999 MHz, Unit: Hz
Max_Drift: float: float Range: -0.99999 MHz/50 μs to 0.99999 MHz/50 μs , Unit: Hz/50 μs
Nominal_Power: float: float Range: -99.99 dBm to 99.99 dBm, Unit: dBm
Freq_Offset: float: float Range: -0.99999 MHz to 0.99999 MHz, Unit: Hz
- class ResultData[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability Indicator’
Out_Of_Tol: float: float Out of tolerance result, i.e. percentage of measurement intervals of the statistic count ([CMDLINK: CONFigure:BLUetooth:MEASi:MEValuation:SCOunt:MODulation CMDLINK]) exceeding the specified limits, see ‘Limits (Modulation LE) ‘. Range: 0 % to 100 %, Unit: %
Delta_F_199_P_9: float: float Range: -0.99999 MHz to 0.99999 MHz, Unit: Hz
Freq_Accuracy: float: float Range: -0.99999 MHz to 0.99999 MHz, Unit: Hz
Freq_Drift: float: float Range: -0.99999 MHz to 0.99999 MHz, Unit: Hz
Max_Drift: float: float Range: -0.99999 MHz/50 μs to 0.99999 MHz/50 μs , Unit: Hz/50 μs
Nominal_Power: float: float Range: -99.99 dBm to 99.99 dBm, Unit: dBm
Freq_Offset: float: float Range: -0.99999 MHz to 0.99999 MHz, Unit: Hz
- calculate() → CalculateStruct[source]
# SCPI: CALCulate:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:LENergy:LRANge:SDEViation value: CalculateStruct = driver.multiEval.modulation.lowEnergy.lrange.standardDev.calculate()
Returns the standard deviation of the modulation results for LE coded PHY, see ‘LE: Statistical Modulation Results ‘. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return
structure: for return value, see the help for CalculateStruct structure arguments.
- fetch() → ResultData[source]
# SCPI: FETCh:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:LENergy:LRANge:SDEViation value: ResultData = driver.multiEval.modulation.lowEnergy.lrange.standardDev.fetch()
Returns the standard deviation of the modulation results for LE coded PHY, see ‘LE: Statistical Modulation Results ‘. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return
structure: for return value, see the help for ResultData structure arguments.
- read() → ResultData[source]
# SCPI: READ:BLUetooth:MEASurement<Instance>:MEValuation:MODulation:LENergy:LRANge:SDEViation value: ResultData = driver.multiEval.modulation.lowEnergy.lrange.standardDev.read()
Returns the standard deviation of the modulation results for LE coded PHY, see ‘LE: Statistical Modulation Results ‘. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return
structure: for return value, see the help for ResultData structure arguments.