Delta
SCPI Command :
CONFigure:BLUetooth:MEASurement<Instance>:MEValuation:LIMit:LENergy:LE2M:DELTa
- class DeltaCls[source]
Delta commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- class DeltaStruct[source]
Response structure. Fields:
Delta_F_2_P_99_P_9: float: numeric Range: 150 kHz to 500 kHz
Delta_F_2_P_99_Enable: bool: OFF | ON Disable/enable limit checking
- get() DeltaStruct [source]
# SCPI: CONFigure:BLUetooth:MEASurement<Instance>:MEValuation:LIMit:LENergy:LE2M:DELTa value: DeltaStruct = driver.configure.multiEval.limit.lowEnergy.le2M.delta.get()
Sets/gets the limit for the frequency deviation Δf2 for LE 2M PHY that must be exceeded by 99.9% of the measured samples.
- return:
structure: for return value, see the help for DeltaStruct structure arguments.
- set(delta_f_2_p_99_p_9: float, delta_f_2_p_99_enable: bool) None [source]
# SCPI: CONFigure:BLUetooth:MEASurement<Instance>:MEValuation:LIMit:LENergy:LE2M:DELTa driver.configure.multiEval.limit.lowEnergy.le2M.delta.set(delta_f_2_p_99_p_9 = 1.0, delta_f_2_p_99_enable = False)
Sets/gets the limit for the frequency deviation Δf2 for LE 2M PHY that must be exceeded by 99.9% of the measured samples.
- param delta_f_2_p_99_p_9:
numeric Range: 150 kHz to 500 kHz
- param delta_f_2_p_99_enable:
OFF | ON Disable/enable limit checking