Faccuracy
SCPI Command :
CONFigure:BLUetooth:MEASurement<Instance>:MEValuation:LIMit:LENergy:LE2M:FACCuracy
- class FaccuracyCls[source]
Faccuracy commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- class FaccuracyStruct[source]
Response structure. Fields:
Freq_Accuracy: float: numeric Range: 0 Hz to 250 kHz
Freq_Acc_Enabled: List[bool]: OFF | ON Disable or enable limit check for current, average, and maximum results (3 values) .
- get() FaccuracyStruct [source]
# SCPI: CONFigure:BLUetooth:MEASurement<Instance>:MEValuation:LIMit:LENergy:LE2M:FACCuracy value: FaccuracyStruct = driver.configure.multiEval.limit.lowEnergy.le2M.faccuracy.get()
Defines the limit for the frequency accuracy. Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
- return:
structure: for return value, see the help for FaccuracyStruct structure arguments.
- set(freq_accuracy: float, freq_acc_enabled: List[bool]) None [source]
# SCPI: CONFigure:BLUetooth:MEASurement<Instance>:MEValuation:LIMit:LENergy:LE2M:FACCuracy driver.configure.multiEval.limit.lowEnergy.le2M.faccuracy.set(freq_accuracy = 1.0, freq_acc_enabled = [True, False, True])
Defines the limit for the frequency accuracy. Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
- param freq_accuracy:
numeric Range: 0 Hz to 250 kHz
- param freq_acc_enabled:
OFF | ON Disable or enable limit check for current, average, and maximum results (3 values) .