Foffset
SCPI Command :
CONFigure:BLUetooth:MEASurement<Instance>:MEValuation:LIMit:LENergy:LE2M:FOFFset
- class FoffsetCls[source]
Foffset commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- class FoffsetStruct[source]
Response structure. Fields:
Freq_Offset: float: numeric Range: 0 Hz to 250 kHz
Freq_Offset_Enable: List[bool]: OFF | ON Disable or enable limit checking for current, average, and maximum results (3 values)
- get() FoffsetStruct [source]
# SCPI: CONFigure:BLUetooth:MEASurement<Instance>:MEValuation:LIMit:LENergy:LE2M:FOFFset value: FoffsetStruct = driver.configure.multiEval.limit.lowEnergy.le2M.foffset.get()
Sets/gets the frequency offset limit. Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
- return:
structure: for return value, see the help for FoffsetStruct structure arguments.
- set(freq_offset: float, freq_offset_enable: List[bool]) None [source]
# SCPI: CONFigure:BLUetooth:MEASurement<Instance>:MEValuation:LIMit:LENergy:LE2M:FOFFset driver.configure.multiEval.limit.lowEnergy.le2M.foffset.set(freq_offset = 1.0, freq_offset_enable = [True, False, True])
Sets/gets the frequency offset limit. Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
- param freq_offset:
numeric Range: 0 Hz to 250 kHz
- param freq_offset_enable:
OFF | ON Disable or enable limit checking for current, average, and maximum results (3 values)